Product Description
NiCr-NiSi (Type K) thermocouple finds the widest use in all basemetal thermocouple, at temperature above 500 ¡ãC.The main chemical composition of positive leg NiCr (KP) are Ni¡Ö90% and Cr¡Ö10%; negative leg NiSi (KN) are Ni¡Ö97% and Cr¡Ö3%. The operating temperature range is -200~1300¡ãC(for short term) and 0~1100¡ãC( for long term) .
Type K thermocouple has strong resistance to oxidation than other base metal thermocouples. It has high EMF against Platinum 67, excellent temperature accuracy, sensitivity and stability, with a low cost. It is recommended for oxidizing or inert atmospheres, but cannot be used directly in the following case:
(1) Alternatively oxidizing and reducing atmosphere,
(2) Atmosphere with sulphur gases,
(3) Long time in vacuum,
(4) Low oxidizing atmosphere such as hydrogen and carbon monoxide atmosphere.
Type K Temperature Range:
(1)Thermocouple grade wire, -200~1300¡æ(for short term) and 0~1100¡æ( for long term)
(2)Extension wire, 32 to 392F (0 to 200C)
Type K Accuracy :
Standard: +/- 1.5C or +/-0.4%t
Working temperature:
Diameter/mm |
Long time Working |
Short period Working |
temperature/¡ãC |
temperature/¡ãC |
0.3 |
700 |
800 |
0.5 |
800 |
900 |
0.8,1.0 |
900 |
1000 |
1.2,1.6 |
1000 |
1100 |
2.0,2.5 |
1100 |
1200 |
3.2 |
1200 |
1300 |